visual centerline to the middle of the instrument. The pilot’s visual centerline is a perpendicular line from the
pilot’s eye to the instrument panel. In most aircraft, installing the MVP-50P to the right of the radio stack
would be acceptable. In some aircraft, the visual centerline falls to the right of the Attitude Indicator.
If the powerplant instrument cannot be installed within 8" of the pilot’s visual centerline, AC 23.1311-1B
recommends Master Caution and Warning Lights be installed. Installation of Master Caution and Warning
Lights is covered in this manual.
Installing the MVP-50P may require an instrument (or two) to be moved to a new location. The MVP-50P
replaces eight or more primary instruments in the aircraft instrument panel, therefore moving an instrument to a
new location may not be an issue. If the installer is unwilling or unable to find a location for the MVP-50P,
DoDo
DoDo
Do
Not InstallNot Install
Not InstallNot Install
Not Install the MVP-50P. The system may be returned for a refund (contact EI for more information).
2.5 Install the Temperature Probes:
Install only the Temperature Probes applicable for your configuration.
A. A.
A. A.
A.
EGT Probe Installation:EGT Probe Installation:
EGT Probe Installation:EGT Probe Installation:
EGT Probe Installation:
Look at each exhaust stack and determine the best location at which all of the EGT probes can be mounted
at the same distance down from the exhaust ports. The ideal location is 1 1/2", but ease of installation should
prevail. For our fast responce probes drill a 5/32 hole or for our robust probes drill a 13/64" diameter hole in
each exhaust stack. Insert the probe and tighten the hose clamp. As the hose clamp is heated and cooled, it
will become loose as it conforms to the exhaust stack. After the first 10 hours of operation, each hose clamp
should be retightened.
IMPORTANT NOTE: For Cessna 210s or any aircraft having a slip joint in the exhaust system, install the
EGT probes ABOVE OR BELOW THE SLIP JOINT. Installing an EGT probe in the slip joint can damage
the probe.
13
P-110 Hose Clamp, Type K.
Used on most engines.
(Red)
(Yel)
To EDC
Temp Input
(Middle or Bottom
Connector)

Table of Contents

Other manuals for Electronics International MVP-50P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Electronics International MVP-50P and is the answer not in the manual?

Electronics International MVP-50P Specifications

General IconGeneral
BrandElectronics International
ModelMVP-50P
CategoryMonitor
LanguageEnglish

Related product manuals