EasyManuals Logo

Electronics International MVP-50P Installation Instructions

Electronics International MVP-50P
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
B. B.
B. B.
B. Do not remove the yellow caps on the flow transducer until the fuel hoses are ready to be installed.
C. C.
C. C.
C. The flow of fuel through the transducer must follow the direction marked on the transducer.
D. D.
D. D.
D. The flow transducer must be mounted so the wires exiting the transducer are pointing up, or the cap
with five bolts is pointing up, or the output port is pointing up, or any combination thereof.
E. E.
E. E.
E. Before connecting any hoses, thoroughly clean them and insure they are free of any loose material.
High air pressure may be used,
however, however,
however, however,
however,
do not allow high air pressure to pass through thedo not allow high air pressure to pass through the
do not allow high air pressure to pass through thedo not allow high air pressure to pass through the
do not allow high air pressure to pass through the
flow transducer.flow transducer.
flow transducer.flow transducer.
flow transducer.
F.F.
F.F.
F. When mounting a Fuel Flow Transducer, make provisions for the Fuel Pressure Transducer as neces-
sary.
G. G.
G. G.
G. If the flow tranducer is hard mounted to a bracket,
DO NOT connect the Black Gound WireDO NOT connect the Black Gound Wire
DO NOT connect the Black Gound WireDO NOT connect the Black Gound Wire
DO NOT connect the Black Gound Wire
on
the flow transducer. The bracket will provide the necessary ground to the transducer.
You may want to consider using some fittings and hoses shown below. Note:
DO NOT EXCEED aDO NOT EXCEED a
DO NOT EXCEED aDO NOT EXCEED a
DO NOT EXCEED a
torque of 15 ft. lbs. or screw the fittings tighter than two full turns past hand tight, which-torque of 15 ft. lbs. or screw the fittings tighter than two full turns past hand tight, which-
torque of 15 ft. lbs. or screw the fittings tighter than two full turns past hand tight, which-torque of 15 ft. lbs. or screw the fittings tighter than two full turns past hand tight, which-
torque of 15 ft. lbs. or screw the fittings tighter than two full turns past hand tight, which-
ever happens first.ever happens first.
ever happens first.ever happens first.
ever happens first.
25
Fittings:Fittings:
Fittings:Fittings:
Fittings:
#4 Straight - AN816-4-4D
#6 Straight - AN816-6D
#8 Straight - AN816-7D
#6 45' - MS20823-6D
#4 90' - MS20822-4-4D
1/4" NPT1/4" NPT
1/4" NPT1/4" NPT
1/4" NPT
FlareFlare
FlareFlare
Flare
Hose Fittings:Hose Fittings:
Hose Fittings:Hose Fittings:
Hose Fittings:
Straight - MS24587-XX, Stratoflex 300-, Aeroquip 400-
45' - MS27226-XX, Stratoflex 646- and 640, Aeroquip 980006
90' - MS27224-XX, Stratoflex 649- and 643, Aeroquip 980005
NOTE: NOTE:
NOTE: NOTE:
NOTE: The Stratoflex teflon hose can be much more flexible
and easier to route than most existing hoses. If you have a hard-
FlareFlare
FlareFlare
Flare
HoseHose
HoseHose
Hose
Important Note:Important Note:
Important Note:Important Note:
Important Note: Aluminum fittings should only be used when flex lines are mounted on the inlet and
outlet ports of the flow transducer. Otherwise, steel, SS or brass fitting should be used.

Table of Contents

Other manuals for Electronics International MVP-50P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Electronics International MVP-50P and is the answer not in the manual?

Electronics International MVP-50P Specifications

General IconGeneral
BrandElectronics International
ModelMVP-50P
CategoryMonitor
LanguageEnglish

Related product manuals