EMC Symmetrix DMX-3 Product Guide
Mainframe Features and Support
Operator messages
On z/OS, SIM messages will be displayed as IEA480E Service Alert
Error messages. They have the format shown in Figure 56 on
page 246 and Figure 57 on page 247.
Figure 56 z/OS IEA480E service alert error message format
(AC power failure)
04CA Moderate SRDF/A drops with reason codes 50, 60, or 62.
04D1 Remote Service Remote connection established. Remote control connected. 14D1
04D2 Remote Service Remote connection closed. Remote control rejected. 14D2
04D3 Service Flex filter problems. 24D3
04D4 Remote Service Remote connection closed. Remote control disconnected. 14D4
04DA Service Problems with task/threads. 24DA
04DB Service SYMPL script generated error. 24DB
04DC Service PC related problems. 24DC
04E0 Remote Failed Communications problems. 14E0
04E1 Service Problems in error polling. 24E1
04F1 Moderate Internal SPS fault. 24F1
04F2 Moderate Internal SPS fault. 24F2
04F3 Moderate No communication to disconnect SPS. 24F3
Table 31 Environmental errors reported as SIM messages (3 of 3)
Hex code Severity alert Description SIM ref code
*IEA480E 1903,SCU,ACUTE ALERT,MT=2105,SER=0507-00025,
REFCODE=247A-0000-0000
247A = AC Line Failure or Interruption
SYM-0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMC Symmetrix DMX-3 and is the answer not in the manual?

EMC Symmetrix DMX-3 Specifications

General IconGeneral
BrandEMC
ModelSymmetrix DMX-3
CategoryStorage
LanguageEnglish

Related product manuals