CONTACT
DISABLED
CONSTANT
100 spm
01 sph
11.00 lph
CONSTANT The pump doses at a constant frequency in relation to the values of “SPH”
(strokes per hour), “SPM” (strokes per minute) or “LPH” (litres per hour) set
during programming.
In the absence of an external signal, hourly dosing of a
product in the desired quantity must be carried out
•
SPH (strokes per hour)
•
SPM (strokes per minute)
•
CONTACT (for external start-up / stop): disabled,
N.O., N.C.
•
LPH (litres per hour) The accuracy of the LPH
depends on the value set in the CC/ST m
enu
(PROG 2 SETUP). The maximum LPH value that
can be set depends on the maximum frequency of
the pump (refer to the data listed on the
nameplate).
When a higher value is set, the pump will display
the # symbol (ALARM STROKE - (
⎘"ALARMS).
Press E on the displayed mode to activate the selection.