TROUBLESHOOTING
Table 10. Troubleshooting.
The pump does not
switch on
•
There is no power supply.
•
Protection fuse blown
•
Faulty circuit
•
Connect the pump to the mains
•
Replace the fuse following ⎘ Fuse
replacement procedure.
•
Replace the circuit following ⎘ Circuit
replacement procedure.
The pump is not
dosing but the
magnet is working
•
Foot filter obstructed
•
Unprimed pump
(suction hose empty)
•
Air bubbles in the
hydraulic circuit
•
Product used generates gas
•
Clean the foot filter
•
Perform the priming procedure
•
Check fittings and hoses and drain
air inside
•
Open the bleed tap to let the air vent
out. Replace the pump body with a
self-purging model
The pump is not dosing
and the magnet is not
working or the stroke
is severely attenuated
•
Crystal formation is
blocking the balls
•
Injection valve obstructed
•
Clean the valves and try circulating 2-
3 litres of water instead of the
chemical
•
Replace valves
Reset to default values by following the ⎘
RESET procedure."
Check the values entered. If correct and
the error is still displayed, the pump may
be undersized
Ask for technical support
Only in mA or Volt working
mode: no input signal
Check pump INPUT (external signal)