mA The current supplied to the pump (via the input signal) determines proportional
dosing according to the two minimum and maximum values in which the strokes
per minute were set during programming.
In the presence of an external current signal, it is
necessary to dose the correct amount of product.
•
HImA (maximum current)
•
LOmA (minimum current)
•
SPM (strokes per minute)
Fig. 24. mA mode
The input signal value (mA) can be displayed when this mode is set.
Caution: if any setting errors occur (e.g. the same value set for HImA and LOmA)
a WRONG ENTRY error screen will appear. Set the correct parameters.
TIMER Weekly programming mode with possibility of repeating up to 16 programs per
week and possibility of setting start time, duration, quantity of product to be
dosed.
One or more (max 16) weekly scheduled dosing
activities are needed
•
Start (start-up time)
•
Time (duration)
•
Quantity (quantity be dosed)
•
Day of the week