Configuration
[50]
2. The parameters Point Id, Serial number of the sensor, and Serial number of the cable on
tab Input.
3. The parameter Output sensitivity on tab Measurement.
Major changes are:
1. The parameters Sensor and Extension cable on the Input tab.
2. All parameters on the Measurement tab except parameter Output sensitivity.
Figure 8-9: Button Send & close
Note
Send & close is disabled after major changes, which require a calibration of the converter, or if the
calibration state of the converter is not OK (see
Calibration state
).
Reload
Click Reload to reload the configuration including the calibration data from the converter to
the configuration editor. The data of the Automatic calibration and the Offline calibration
(calibration process without Machine Studio) is loaded as Manual calibration data. Use the
report function to display the calibration data. Any configuration changes you made in
Machine Studio will be overwritten by the configuration loaded from the converter.
Figure 8-10: Button Reload
Reset to factory default
Click Reset to factory default to reset the connected converter to the default parameter
settings.