4
Figure 5
BLK WHT
SENSOR
TO HEATING
CABLE
L 2
L 1 (N)
L
1 (N) L
2
INPUT POWER
To Ground Connection
Sensor Wire
Heating Cable
Cold Lead
Power Supply Cable
BLK WHT
SENSOR
TO HEATING
CABLE
L 2
L 1 (N)
L
1 (N) L
2
INPUT POWER
Heating Cable
Cold Leads
Power Supply Cable
Sensor Wire
To Ground Connection
Figure 6
per Figure 8 shown and will continue to flash until
timeisset.ThetimecanbesetbypressingtheUpor
Downbuttons.NotethatifyoupressandholdtheUp
orDownbuttons,theMinuteschangecontinuously
(andthenthehoursandthenAM/PM)andtherate
of change gradually increases. Once the time is set,
presstheNext/Savebuttontosettheday-usetheUp
orDownbuttonstoadjustday.PresstheNext/Save
buttononcetofinishandexitfirsttimesetting.
No additional changes to any settings are allowed
unlesstheOn/OffbuttonissettoOnmode.
D. Quick Start
The thermostat is pre-programmed for immediate
operationinthe5/2mode.PresstheOn/Off
button to On position; the thermostat will control
the floor temperature to a moderate temperature
(86°F/30°C)suchthatthecablesareonlyenergized
in the morning and the evening, and off during the
dayandthenight.Theexactscheduleofoperation
isasfollows:
AutomaticProgramforWeekdays
Event Time Floor Temp
Wake 6:00am 86°F/30°C
Leave 8:00am 60°F/16°C
Return 5:00pm 86°F/30°C
Sleep 10:00pm 60°F/16°C
AutomaticProgramforWeekends
Event Time Floor Temp
Wake 6:00am 86°F/30°C
Leave 8:00am 60°F/16°C
Return 5:00pm 86°F/30°C
Sleep 10:00pm 60°F/16°C
Formanualoperation,presstheUporDownbutton
once and adjust setpoint temperature to desired
setting,PresstheHoldbuttononce–thistemporarily
adjusts the setpoint temperature to the desired
setting – the setpoint temperature will revert to
AutomaticProgramatthebeginningofthenext
Eventasnotedabove.Byimmediatelypressingthe
Hold button a second time, this permanently sets
the setpoint temperature at the desired setting.
E. Settings
TheSettingsmenuwillallowyoutochangetheTime/
Day,Units(ForC),Program,BacklightTimeandFloor
Type.BypressingtheSettingsbutton,youenterthe
Setting menus. You can scroll through the various
menusbypressingtheNext/Savebutton(“Advance
toNextMenu”).Onceinamenu,youcanchange
the“flashing”parametersbyusingtheUporDown
buttons.PressingtheNext/Savebuttonacceptsthe
changesandscrollstonextmenu.
ToexitSettingsmenuswithoutsavingchangesatany
time (“Exit Without Saving”),pressandholdBack/
Cancel button for two seconds.
TosavechangesandexitSettingsmenus,pressand
holdNext/Savebuttonfortwoseconds(“Save and
Exit”).
Ifnokeyispressedfor90secondstheprogramwillexit
the Settings menus, save all changes that have been
accepted and return to normal display.