100      Appendix 1  Parameters 
EV2000 Series Universal Variable Speed Drive    User Manual 
Group 7: Terminal Function Parameters 
Para.  Name  LCD Display  Setting Range  Unit 
Factory 
setting
Modif
reaches 
reference value 
VALUE 
F7.35 
Terminal’s 
positive and 
negative logic 
TERMINAL 
ENABLE 
STATE 
Binary setting: 
Positive logic: Terminal Xi is enabled if it is connected to 
corresponding common terminal, and disabled if it is disconnected; 
Negative logic: Terminal Xi is disabled if it is connected to 
corresponding common terminal, and enabled is it is disconnected; 
Unit’s place of LED:      Bit0~Bit3:X1~X4 
Ten’s place of LED:      Bit0~Bit3:X5~X8 
Hundred’s place of LED:    Bit0~Bit1:FWD. REV, Bit2~Bit3:Y1. Y2 
1 000 
○ 
 
Group F8: Display Parameters 
Para.  Name  LCD Display  Setting Range  Unit 
Factory 
Setting
Modif.
F8.00 
Language selection 
(Chinese/ English) 
LANGUAGE 
SELECT 
0:Chinese     1:English 
Note: This function is only applicable for LCD panel 
1 0 
○ 
F8.01 
Parameter group 1 
displayed during operation   
OPR DISPLAY1 
 
(Not flash,  ▲ 
and  ▼ keys are 
valid only in 
frequency and 
speed displaying 
status; The 
status will be 
saved at power 
off) 
Binary settings: 
0:No display;     1:Display 
Unit’s place of LED: 
Bit0: Output frequency (Hz) (before compensation) 
Bit1: Output frequency (Hz) (after compensation) 
Bit2: Reference frequency (Hz flashes)   
Bit3:Output current(A) 
Ten’s place of LED: 
Bit0:Spinning speed(R/MIN) 
Bit1:Reference speed(R/MIN flashes) 
Bit2: Line speed(M/S) 
Bit3:Reference line speed(M/S flashes)     
Hundred’s place of LED: 
Bit0:Output power 
Bit1:Output torque(
%) 
Note: The frequency before compensation will be 
displayed if all the Bits are 0. 
1 3FF 
○ 
F8.02 
Parameter group 1 
displayed during operation   
OPR DISPLAY2   
 
(nor flash; the 
status will be 
saved at power 
off) 
Binary settings: 
0:No display; 1:Display 
Unit’s place of LED: 
Bit0:Output voltage(V)        Bit1:Bus voltage 
Bit2:VCI(V)         Bit3:CCI(V) 
Ten’s place of LED: 
Bit0: Analog close loop feedback(%) 
Bit1: Analog close loop feedback(% flashes) 
Bit2: External counting value(no unit) 
Bit3: Terminal status(no unit) 
Hundred’s place of LED: 
Bit0: Actual length            Bit1: reference length 
1 000 
○