102 Appendix 1 Parameters
EV2000 Series Universal Variable Speed Drive User Manual
Group F9: Enhanced Functional Parameters
Para. Name LCD Display Setting range Unit
Factory
setting
Modif.
F9.00
Control mode is
bundled to
frequency
selector
FREQ-COM
MAND
ATTACHING
Unit’s place of LED: Select the frequency reference selector in
panel control mode
0:No bundling
1:Digital setting 1(set via and )
2:Digital setting 2(set via terminal UP/DN)
3:Digital setting 3(set via serial port)
4:Set the reference via VCI
5:Set the reference via CCI
6:Set in pulse mode via terminals
Ten’s place of LED: Select the frequency reference selector in
terminal control mode
0: No bundling
1:Digital setting 1(set via and )
2:Digital setting 2(set via terminal UP/DN)
3:Digital setting 3(set via serial port)
4:Set the reference via VCI
5:Set the reference via CCI
6:Set in pulse mode via terminals
Hundred’s place of LED: Select the frequency reference selector
in serial port control mode
0: No bundling
1:Digital setting 1(set via and )
2:Digital setting 2(set via terminal UP/DN)
3:Digital setting 3(set via serial port)
4:Set the reference via VCI
5:Set the reference via CCI
6:Set in pulse mode via terminals
1 000
F9.01
Auxiliary
reference
channel
AUX REF
0:No auxiliary reference frequency;
1:Digital setting 1, set by and (given by F9.03 directly);
2:Digital setting 2, set by terminal UP/DN (given by F9.03
directly);
3:Digital setting 3, set by serial port(given by F9.03 directly);
4:Set the reference via VCI
5:Set the reference via CCI
6:Set in pulse mode via terminals
4:Set the reference via VCI
5:Set the reference via CCI
9:Set in pulse mode via terminals
10:VCI-5;
11:CCI-5;
12:PULSE-0.5×F1.03
Note: Disabled together with main reference selector frequencies
in items 4~12 use the setting of F1.00.
1 0
F9.02
Auxiliary
reference
coefficient
AUX REF
FACTOR
0.00~9.99(only for F9.01=4~12) 0.01 1.00
F9.03
Initial auxiliary
frequency
AUX FREQ 0.00~650.0Hz 0.01 0.00Hz
F9.04
Auxiliary
frequency
control
AUX FREQ
CTR
Unit’s place of LED: Saving control
0:Saving auxiliary frequency at power off
1:Not saving auxiliary frequency at power off
Ten’s place of LED:
0:Holding auxiliary frequency at stop
1:Clearing reference frequency at stop
Hundred’s place of LED: polarities of frequency
0:Positive 1:Negative
Note: Only valued at F9.01=1, 2 or 3
1 000