Diameter of terminal
Enlarged view of terminal
Mounting hole
Mounting hole
Fig. 2-3 Dimensions of DC reactor
Table 2-6 Mechanical Parameters of DC Reactor
Applicable
drive
(kW)
Model of DC
reactor
Recommended
size of copper
mm
2
Size(mm)
Gross
weight
(kg)
A B C D E F G H I J
Diameter
of terminal
75G
TDL-4DI01-0900 60 190 160 125 161 120 80 10 250 280 25
φ
12
23
90G/90P
110G/110P TDL-4DI01-1100 100 190 160 125 161 120 80
10
250
280
25
φ
12
25
132G/132P TDL-4DI01-1320 150 200 170 135 171
120
85
10
260
280
30
φ
12
28
160G/160P TDL-4DI01-1600 150 210 180
135 171
130 85 12 280 320 30
φ
12
32
200G/200P
TDL-4DI01-2200
200
220 190
135 171
150 90
12
315 340 40
φ
15
40
220G/220P 250
280P TDL-4DI01-2800 325
220 190
145 181 160 95
12 315
340 40
φ
15
45
Notes:
1. Columns B and C in Table 2-6 are the sizes of mounting holes of DC reactor.
2. DC reactor should be installed at the bottom of the cabinet if it is to be installed inside a cabinet. The clearance between reactor
and the drive should be at least 35cm, and the reactor should be as far away from the air inlet port of the drive as possible.