18
Safety Manual
00809-0200-5100, Rev GB
Installation and Configuration
February 2017
Installation and Configuration
Figure 4-6. SIL Alarm relay output for a 5900 (1-in-1) complying with SIL 2
Rosemount 2410
Rosemount 5900 (2-in-1)
Rosemount 2410
Rosemount 2410
Rosemount 5900 (2-in-1)
SIL Alarm Relay output to
emergency shut-down system
SIL Alarm Relay output to
emergency shut-down system
Ta nk bus
Ta nk bus
SIL Alarm
SIL Alarm
SIL Alarm
Relay
SIL Alarm
Relay
SIL Alarm triggered by one or
more of:
SIL High/Low Alarm
Internal error
Not configured
Not approved