Tab le D- 1 lists possible measurement status messages that may appear.
Table D-1. SIL Measurement Status
Several messages can be combined. If, for example, the two messages Amplitude peak detected
in alarm area and PM Device Error appear simultaneously the result would be:
0x00000001 Hex + 0x04000000 Hex = 0x04000001 Hex.
Contact Emerson Process Management/Rosemount Tank Gauging service department to report
failures.
Hexadecimal Value Description
0x00000001 Surface Amplitude peak detected in alarm area
•No peak detected
0x00000002 Other query is being processed. Wait for next
update. E.g. reading input/holding registers at the
same time as parameterization.
0x00000003 Contact Emerson Process Management/Rosemount
Tank Gauging service department
0x00000004 - 0x0000000F Contact Emerson Process Management/Rosemount
Tank Gauging service department.
For exceptions see below:
0x00000008
0x00000009
No peak detected in this measurement
Alarm due to no peak found
0x00000010 - 0x000000F0 Information only
0x00000180 Single measurement failure (sweep failed). Wait for
another update of measurement data.
0x00000200 - 0x00000F00 Contact Emerson Process Management/Rosemount
Tank Gauging service department
0x00001000 - 0x0000F000 Information only except for the two cases listed
below:
0x00008000 Important!
0x00008008 Important!
Diagnostics performed. Wait for another update of
measurement data.
0x00010000 - 0x000F0000 Contact Emerson Process Management/Rosemount
Tank Gauging service department
0x00100000 - 0x00F00000 Not used
0x04000000 PM Device Error
0x01000000 - 0x03000000 Contact Emerson Process Management/Rosemount
Tank Gauging service department
0x05000000 - 0x0F000000
0x10000000 - 0xF0000000 Not used