- 159 -
Chapter 9. Standard Input/ Output Signal
21) Movement velocity override signal during automatic operation(in) [
M97.8
],OV1~OV8[
M97.0~M97.3
]
If the input signal OVE is closed(1), then the movement velocity by ‘VEL’ changes to 16 steps
(0%~150%) by OV1, OV2, OV4, OV8, on the other hand, if the input signal OVE is opened(0), then the
OV1, OV2, OV4, OV8 are ignored.
OVE[M97.8] OV8[M97.3] OV4[M97.2] OV2[M97.1] OV1[M97.0] Percentage
1 0 0 0 0 0 %
1 0 0 0 1 10 %
1 0 0 1 0 20 %
1 0 0 1 1 30 %
1 0 1 0 0 40 %
1 0 1 0 1 50 %
1 0 1 1 0 60 %
1 0 1 1 1 70 %
1 1 0 0 0 80 %
1 1 0 0 1 90 %
1 1 0 1 0 100 %
1 1 0 1 1 110 %
1 1 1 0 0 120 %
1 1 1 0 1 130 %
1 1 1 1 0 140 %
1 1 1 1 1 150 %
0 X X X X 100 %
22) Movement velocity override signal(in) during manual operation JOVE [M97.9],JOV1~JOV8[M97.4~M97.7],JOT[M97.F]
If the input signal JOVE is closed(1) and JOT is opened(0), then the manual feed velocity is changed
into 16 steps(0~150%) by the JOV1,JOV2,JOV4,JOV8, on the other hand, if JOVE and JOT are closed(1),
then the manual feed velocity changes to a setting value(X-axis:60~75, Y-axis:80~95) from the L Var
Table.
If the input signal JOVE is opened(0), then the JOV1, JOV2, JOV4 and JOV8 are ignored..
JOVE[M97.9] JOT[M97.F] JOV8[97.7] JOV4[M97.6] JOV2[M97.5] JOV1[M97.4]
Percentage
1 0 0 0 0 0 0%
1 0 0 0 0 1 10%
1 0 0 0 1 0 20%
1 0 0 0 1 1 30%
1 0 0 1 0 0 40%
1 0 0 1 0 1 50%
1 0 0 1 1 0 60%
1 0 0 1 1 1 70%
1 0 1 0 0 0 80%
1 0 1 0 0 1 90%
1 0 1 0 1 0 100%
1 0 1 0 1 1 110%
1 0 1 1 0 0 120%
1 0 1 1 0 1 130%
1 0 1 1 1 0 140%
1 0 1 1 1 1 150%
0 X X X X X 100%