2.3. Powder Chambers
Clinical risk: Only use PLUS or PERIO Powder with the PLUS Powder chamber.
Clinical risk: Only use PLUS Powder chamber (red) for subgingival treatments.
PLUS
The PLUS Powder chamber is designed for the PLUS Powder. It can be
used for supra and subgingival treatments.
Pressure is automatically reduced for compatibility with subgingival treatments,
including Perioflow treatments (Supra applications also possible).
Compatible EMS Powders: PLUS and PERIO (refer to paragraph “Compatibility
for details).
CLASSIC
The CLASSIC Powder chamber is designed for the CLASSIC Powder and
can only be used for supragingival treatments.
Sodium Bicarbonate: Use only this powder
and chamber for supragingival
applications.
Compatible EMS P
owders: CLASSIC and SOFT (refer to paragraph
Compatibility” for details).
Check bottle and powder chamber integrity: There should be no crack on the body.
The powder chamber is pressurized during use. Replace faulty parts immediately.
Make sure that the powder chambers are dry.
Use only PLUS or PERIO Powders for restorations, crowns, bridgework, implants and
orthodontics.
Do not sterilize the powder chambers and their caps/parts by steaming or dry thermal
reprocessing. Use only ambient temperature active disinfectant and cleaning agents.
By hand only: remove the powder chamber cap to refill
powder up to the indicated MAX level, then insert the cap
back fully onto the bottle.
Pour the powder in freely. The central tube can be fully
filled without problem.
Do not fill the chamber higher than the indicated MAX
level. The powder level will go down slightly a few minutes
after the filling (powder compaction).
Before pressurizing, position the powder chamber into the
device. Magnetic attraction will position it correctly.
Do not insert upside-down.

Other manuals for EMS AIRFLOW Prophylaxis Master

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EMS AIRFLOW Prophylaxis Master and is the answer not in the manual?

EMS AIRFLOW Prophylaxis Master Specifications

General IconGeneral
Water Flow RateAdjustable
Powder Flow RateAdjustable
TechnologyAIRFLOW, PERIOFLOW, PIEZON
Water SupplyIntegrated water tank
ControlFoot control
HandpiecesAIRFLOW, PERIOFLOW, PIEZON
Water tank capacityApprox. 800 ml
Water pressure1 - 5 bar (100 - 500 kPa)
Operating modeContinuous
TypeAir polishing system
Powder TypeErythritol, Glycine
Nozzle TypesStandard, Perio
Power Supply100-240 V, 50/60 Hz