17. APPENDIX
17.1. PROBE COMPATIBILITY TABLE
Different probe sizes are available to allow effective treatment with the most popular endoscopic systems for percu-
taneous nephroscopy, rigid and semi-rigid ureteroscopy and cystoscopy:
PROBE DIAMETER
AND LENGTH
MINIMUM ENDOSCOPE
WORKING CHANNEL
SIZE
MAXIMUM ENDOSCOPE
WORKING CHANNEL
LENGTH
TAG RING COLOR
Ø 1.1 mm x 425 mm 4 Fr 400 mm RED
Ø 1.1 mm x 520 mm 4 Fr 500 mm RED
Ø 1.1 mm x 625 mm 4 Fr 600 mm RED
Ø 1.5 mm x 425 mm 5 Fr 400 mm ORANGE
Ø 1.5 mm x 520 mm 5 Fr 500 mm ORANGE
Ø 1.9 mm x 341 mm 6 Fr 320 mm YELLOW
Ø 3.4 mm x 340 mm 10.5 Fr 320 mm GREEN
Ø 3.4 mm x 445 mm 10.5 Fr 420 mm GREEN
Ø 3.9 mm x 350 mm 12 Fr 330 mm BLUE
Ø 3.9 mm x 440 mm 12 Fr 420 mm BLUE
Table 17
* US and suction not available
17.2. FCC AND IC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modications not expressly approved by Electro Medical Systems for compliance could void the user’s
authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
FCC RF exposure statement:
Important note: This device complies with FCC and Industry Canada radiation exposure limits set forth for general
population. This device must not be co-located or operating in conjunction with any other antenna or transmitter.
IC Statements:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following
two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Under Industry Canada regulations, the radio transmitter(s) in this device may only operate using an antenna of a
type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio inter-
ference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated
power (e.i.r.p.) is not more than that necessary for successful communication.