Gammapilot M FMG60 XA00303F-G
Endress+Hauser 19
Circuit 4...20 mA/HART (active) in type of protection Intrinsic safety (Ex ia)
Basic specification, Position 3 (Connect. Power Supply; Connect. Output) = B, E, J, K
A
5
7 8 9
10
12
15
6
2
3
1
B
13
14
4
6
5
11
A0031754
7
A Zone 1 or Zone 2
B Zone 0, Zone 1 or Zone 2
1 Local potential equalization line
2 PT100; approved Ex ia equipment
3 Gammapilot with NaJ crystal scintillator, PVT plastic scintillator
4 [Ex ia] circuit
5 Terminal compartment A (Ex db or Ex eb)
6 Terminal compartment B (Ex i)
7 [Ex ia] circuit; Cascade in, out
8 [Ex ia] circuit
9 Communication: 4...20 mA/HART active [Ex ia]
10 Power supply
11 Certified associated apparatus
12 Remote display FHX40
13 Certified associated apparatus
14 Communication: 4...20 mA/HART active [Ex ia]
15 Gammapilot with NaJ crystal scintillator, PVT plastic scintillator