XA00303F-G Gammapilot M FMG60
18 Endress+Hauser
Position 5 (Scintillator; Measuring Range)
Selected option Description
FMG60 A-D NaJ-Crystal
G-T PVT
Optional specifications
No options specific to hazardous locations are available.
Safety instructions: General
Observe also XA00304F for the device versions marked with II 2(1) G and II 2(1) D:
Basic specification, Position 1 (Approval) = 6, 7, 8, M.
Comply with the installation and safety instructions in the Operating Instructions.
Staff must meet the following conditions for mounting, electrical installation, commissioning and
maintenance of the device:
Be suitably qualified for their role and the tasks they perform
Be trained in explosion protection
Be familiar with national regulations
Install the device according to the manufacturer's instructions and national regulations.
Do not operate the device outside the specified electrical, thermal and mechanical parameters.
Avoid electrostatic charging:
Of plastic surfaces (e.g. housing, sensor element, special varnishing, attached additional
plates, ..)
Of isolated capacities (e.g. isolated metallic plates)
Safety instructions:
Special conditions
In the event of additional or alternative special varnishing on the housing or other metal parts:
Observe the danger of electrostatic charging and discharge.
Do not rub surfaces with a dry cloth.
Do not install in the vicinity of processes generating strong electrostatic charges.
Safety instructions:
Installation
1
2
3
4
A0031753
 6
1 Pipe housing
2 Compartment housing
3 Terminal compartment A
4 Terminal compartment B