EasyManua.ls Logo

Endress+Hauser Levelflex M FMP40 Brief Operating Instructions

Endress+Hauser Levelflex M FMP40
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
KA01040F/00/EN/13.10
71120279
Brief Operating Instructions
Levelflex M FMP40
Guided Level-Radar
These are Brief Operating Instructions.
For more detailed information, please refer to the Operating Instructions and the
additional documentation on the CD-ROM provided.
These Brief Operating Instructions are not intended to replace the Operating
Instructions provided in the scope of supply.
The complete device documentation consists of:
these Brief Operating Instructions
Approvals and safety certificates
a CD-ROM with:
the Operating Instructions
Technical Information

Other manuals for Endress+Hauser Levelflex M FMP40

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Levelflex M FMP40 and is the answer not in the manual?

Endress+Hauser Levelflex M FMP40 Specifications

General IconGeneral
CommunicationHART, PROFIBUS PA, FOUNDATION Fieldbus
TypeLevel sensor
Device TypeFMP40
ApplicationLevel measurement
Measuring PrincipleTDR (Time Domain Reflectometry)
Measuring RangeUp to 30 m
Process Temperature-40 to +150 °C (-40 to +302 °F) (depending on probe and process connection)
Process Pressure-1 to 40 bar (-14.5 to 580 psi)
Accuracy± 2 mm
Output Signal4-20 mA, HART
Power Supply10-30 V DC
MaterialStainless steel, PTFE
Housing MaterialAluminum
Protection ClassIP68
ApprovalsATEX, IECEx
Probe TypeRod, cable