Commissioning Levelflex M FMP40 FOUNDATION Fieldbus
32 Endress+Hauser
The lower group applies to very loose or loosened bulk solids. Reduction of the max. possible
measuring range by means of:
Extremely loose surfaces of bulk solids, e.g. bulk solids with low piled density when filled
pneumatically.
Build-up, primarily of moist products.
!
Note!
Due to the high diffusion rate of ammonia it is recommended to use the FMP45 with gas-tight
bushing for measurements in this medium.
Media
group
DC (εr) Typical bulk solids Typical liquids
Measuring range
bare metallic
probes
PA-coated rope
probes
1 1.4 to 1.6
Condensed gases, e.g. N
2
,
CO
2
4 m (157"), only
coax probe
2 1.6 to 1.9
Plastic granulate
White lime, special cement
–Sugar
Liquefied gas, e.g. Propane
–Solvent
Frigen / Freon
–Palm oi
25 m to 30 m
(984" to 1181")
12,5 m to 15 m
(492" to 590")
3 1.9 to 2.5
Portland cement, plaster Mineral oils, fuels 30 m to 35 m
(1181" to 1378")
Flour 15 m to 25 m
(590" to 984")
4 2.5 to 4
Grain, seeds ⎯⎯25 m to 30 m
(984" to 1181")
–Ground stones
–Sand
Benzene, styrene, toluene
–Furan
Naphthalene
35 m (1378")
25 m to 30 m
(984" to 1181")
5 4 to 7
Naturally moist (ground)
stones, ores
–Sal
Chlorobenzene,
chloroform
Cellulose spray
Isocyanate, aniline
35 m (1378") 35 m (1378")
6 >7
Metallic powder
Carbon black
–Coa
Aqueous solutions
Alcohols
–Ammonia
35 m (1378") 35 m (1378")