Installation Liquicap M FTI51, FTI52
20 Endress+Hauser
Rod probes ∅16, rope probes
For pressures up to 25 bar 100 bar 25 bar 100 bar 40 bar 16 bar** 16 bar** 16 bar** 16 bar**
Version / order code G ¾ / GDJ
G 1 / GEJ
G 1½ /
GGJ
NPT ¾/
RDJ
NPT 1 /
REJ
NPT 1½/
RGJ
DN50 PN40 / MRJ DN38 /
TNJ
(1½")
DN40-51 /
TDJ
(2")
DN38 /
TJK
(1½")
DN40-51
TDK
(2")
Dimensions H2 = 38
H3 = 19
AF = 41
H2 = 41
H3 = 25
AF = 55
H2 = 38
H3 = 19
AF = 41
H2 = 41
H3 = 25
AF = 55
H2 = 66 H2 = 47 H2 = 66 H2 = 66
Surface roughness*** -- -- ≤ 0.8 μm ≤ 0.8 μm ≤ 0.8 μm ≤ 0.8 μm
Additional information Elastomer flat seal -- -- EHEDG*
3A*
-- EHEDG, 3A
* The EHEDG, 3A certificate only applies to probes with a fully insulated probe rod. It does not apply to probes with an inactive length or active buildup
compensation.
** In the event of CRN approval, the maximum permitted process pressure is 11 bar.
*** Does not apply for inactive lengths.
Rod probes ∅22, rope probes
For pressures up to 50 bar 50 bar -- -- --
Version / order code G 1½ / GGJ NPT 1½/ RGJ -- -- --
Dimensions H2 = 85
H3 = 25
AF = 55
H2 = 85
H3 = 25
AF = 55
-- -- --
Additional information Elastomer flat seal -- -- -- --
Thread G Thread NPT Threaded pipe joint Tri–Clamp Tri-Clamp clad
Flanges Hygiene connection Hygiene connection Hygiene connection
L00-FMI5xxxx-06-05-xx-xx-042
(EN1092-1)
(ANSI B 16.5)
(JIS B2220)
L00-FMI5xxxx-06-05-xx-en-009
With flush-mounted seal
L00-FMI5xxxx-06-05-xx-en-010
With flush-mounted seal
L00-FMI5xxxx-06-05-xx-xx-043
Adapter 44 mm
with flush-mounted seal
Rod probes ø10, rope probes
For pressures up to Max. 25 bar (depends on flange) 25 bar 25 bar --
Version / order code EN / B**
ANSI / A**
JIS /K**
G ¾ / GQJ G 1 / GWJ --
Dimensions H2 = 57 H2 = 31
H3 = 26
AF = 41
H2 = 27
H3 = 30
AF = 41
--
Additional information Also clad (PTFE) Welding neck
see "Accessories"
EHEDG*, 3A*
Welding neck
see "Accessories"
EHEDG*, 3A*
--
* The EHEDG, 3A certificate only applies to probes with a fully insulated probe rod. It does not apply to probes with an inactive length
or active buildup compensation.
** Wildcard for nominal diameter and permitted process pressure
Note! Only use clad flanges for aggressive liquids!
H2
H2
H3
AF
H2
H3
AF
H2