EasyManua.ls Logo

Endress+Hauser Liquiphant FTL51B - Page 26

Endress+Hauser Liquiphant FTL51B
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connection Liquiphant FTL51B
26 Endress+Hauser
Terminal assignment
>0,5
COM
MIN
MAX
>0,7
+
1
2
L- L+
!
!
7
33
37
d4
z4
8
34
38
d2
z2
z6 d6
.
-
1 2
A0036065
 27 PFM output, electronic insert FEL67
7/ 8: Nivotester FTL325P 1 CH, FTL325P 3 CH input 1
33/ 34: Nivotester FTL325P 3 CH input 2
37/ 38: NivotesterFTL325P 3 CH input 3
d4/ d2: Nivotester FTL375P input 1
z4/ z2: Nivotester FTL375P input 2
z6/ d6: Nivotester FTL375P input 3
Connection cable
Maximum cable resistance: 25 Ω per core
Maximum cable capacitance: < 100 nF
Maximum cable length: 1 000 m (3 281 ft)

Table of Contents

Other manuals for Endress+Hauser Liquiphant FTL51B

Related product manuals