Liquiphant FTL51B Technical data
Endress+Hauser 55
14.3.4 Operating altitude
As per IEC 61010-1 Ed.3:
Up to 2 000 m (6 600 ft) above sea level
Can be extended to 3 000 m (9 800 ft) above sea level if overvoltage protection is used
14.3.5 Climate class
As per IEC 60068-2-38 test Z/AD
14.3.6 Degree of protection
For housing with electrical connection
M20 coupling, plastic
Single-chamber, plastic: IP66/67 NEMA type 4X
Single-chamber and dual-chamber, aluminum: IP66/68 NEMA type 4X/6P
Single-chamber 316L, cast: IP66/68 NEMA type 4X/6P
M20 coupling, nickel-plated brass
Single-chamber and dual-chamber, aluminum: IP66/68 NEMA type 4X/6P
M20 coupling, 316L
Single-chamber and dual-chamber, aluminum: IP66/68 NEMA type 4X/6P
Single-chamber 316L, cast: IP66/68 NEMA type 4X/6P
Thread M20
Single-chamber, plastic: IP66/67 NEMA type 4X
Single-chamber and dual-chamber, aluminum: IP66/68 NEMA type 4X/6P
Single-chamber 316L, cast: IP66/68 NEMA type 4X/6P
Thread G ½
Single-chamber, plastic: IP66/67 NEMA type 4X
Single-chamber and dual-chamber, aluminum: IP66/68 NEMA type 4X/6P
Single-chamber 316L, cast: IP66/68 NEMA type 4X/6P
Thread NPT ½
Single-chamber, plastic: IP66/67 NEMA type 4X
Single-chamber 316L, cast: IP66/68 NEMA type 4X/6P
Thread NPT ¾
Single-chamber and dual-chamber, aluminum: IP66/68 NEMA type 4X/6P
Single-chamber 316L, cast: IP66/68 NEMA type 4X/6P
M12 plug
Single-chamber, plastic: IP66/67 NEMA type 4X
Single-chamber, aluminum: IP66/67 NEMA type 4X
Single-chamber 316L, cast: IP66/67 NEMA type 4X
14.3.7 Vibration resistance
As per IEC60068-2-64-2009
a(RMS) = 50 m/s², f = 5 to 2 000 Hz , t = 3 planes x 2 h
For increased oscillations or vibrations, the additional option of order code "Application"
option "B" 100 bar (1 450 psi) process pressure is recommended.
14.3.8 Shock resistance
As per IEC60068-2-27-2008: 300 m/s² [=30 gn] + 18ms