Liquiphant M FTL51C
8 Endress+Hauser
Electronic insert FEL52 (DC PNP)
Power supply Supply voltage: DC 10 to 55 V
Ripple:
1.7 V, 0 to 400 Hz
Current consumption: 15 mA
Power consumption: 0.83 W
Reverse polarity protection
Overvoltage protection FEL52: overvoltage category III
Electrical connection Three-wire DC connection
Output signal
Signal on alarm Output signal on power failure or in the event of damaged sensor: < 100 μA
Connectable load Load switched via the transistor and separate PNP connection,
DC 55 V
•Load current
350 mA (pulsed overload and short-circuit protection)
Residual current < 100 μA (with transistor blocked)
Capacitance load 0.5 μF at 55 V, 1.0 μF at 24 V
Residual voltage < 3 V (with transistor switched through);
Switches the load via the transistor (PNP) and
separate connection.
Preferably used with programmable logic
controllers (PLC),
DI modules as per EN 61131-2.
Positive signal at switching output of the
electronics (PNP); Output blocked on reaching
point level.
L00-FTL5xxxx-04-05-xx-xx-030
1 2 3
(+)
FEL52
L+
L–
0.5 A
U– 10…55 V DC
...
Relais,
PLC, ...
PE
(Ground)
R
Safety mode Level Output signal LEDs
green red
I
L
< 100 μA
L00-FTL2xxxx-07-05-
xx-xx-000
= load current
(switched through)
= residual current
(blocked)
= lit
= unlit
L00-FTL5xxxx-04-05-xx-xx-004
MAX
MIN
L+ +
1 3
L+ +
1 3
1 3
1 3
I
L
I
L
< 100 μA
< 100 μA

Table of Contents