Micropilot FMR10 Installation
Endress+Hauser 13
L
D
L
D
A0028843
 4 Nozzle mounting
L Nozzle length
D Nozzle diameter
The maximum length of the nozzle L depends on the nozzle diameter D.
Please note the limits for the diameter and length of the nozzle.
Mounting outside the nozzle
D: min. 40 mm (1.5 in)
L: max. D × 1.5
Mounting inside the nozzle
D: min. 80 mm (3 in)
L: max. 140 mm (5.5 in) + D × 1.5