Technical data Levelflex M FMP40 with PROFIBUS PA
110 Endress + Hauser
Extension of the rope probes
through tension and
temperaturer
6 mm rope:
• Elongation through tension: at max. permitted tensile load (30 KN): 13 mm / m rope length
• Elongation through temperature increase from 30 °C to 150 °C: 2 mm / m rope length
4 mm rope:
• Elongation through tension: at max. permitted tensile load (12 KN): 11 mm / m rope length
• Elongation through temperature increase from 30 °C to 150 °C: 2 mm / m rope length
10.1.6 Mechanical construction
Tolerance of probe length
Weight
Material • Housing:
– housing F12/T12: aluminium (AlSi10Mg), seawater-resistant, chromated, powder-coated
– housing F23: 316L, corrosion-resistant steel
• Sight window: glass
Process connection See "Ordering structure" on → ä 8.
Seal See "Ordering structure" on → ä 8.
Probe See "Ordering structure" on → ä 8.
Rod probes
over 1 m / 3.2 ft 3 m / 9.8 ft 6 m / 20 ft
up to 1 m / 3.2 ft 3 m / 9.8 ft 6 m / 20 ft
admissible tolerance (mm / inch) - 5 / - 0.2 - 10 / - 0.4 - 20 / - 0.8 - 30 / - 1.2
Rope probes
over 1 m / 3.2 ft 3 m / 9.8 ft 6 m / 20 ft
up to 1 m / 3.2 ft 3 m / 9.8 ft 6 m / 20 ft
admissible tolerance (mm / inch) - 10 / - 0.4 - 20 / - 0.8 - 30 / - 1.2 - 40 / - 1.6
Levelflex M FMP40
+ rope probe
4mm
FMP40
+ rod or rope probe
6mm
FMP40
+ rod probe
16 mm
FMP40
coax probe
Weight for F12 or
T12 housing
Approx. 4 kg
+
Approx. 0.1 kg/m
probe length
+
weight of flange
Approx. 4 kg
+
Approx. 0.2 kg/m
probe length
+
weight of flange
Approx. 4 kg
+
Approx. 1.6 kg/m
probe length
+
weight of flange
Approx. 4 kg
+
Approx. 3.5 kg/m
probe length
+
weight of flange
Weight for F23
housing
Approx. 7.4 kg
+
Approx. 0.1 kg/m
probe length
+
weight of flange
Approx. 7.4 kg
+
Approx. 0.2 kg/m
probe length
+
weight of flange
Approx. 7.4 kg
+
Approx. 1.6 kg/m
probe length
+
weight of flange
Approx. 7.4 kg
+
Approx. 3.5 kg/m
probe length
+
weight of flange