Levelflex M FMP40 with PROFIBUS PA Technical data
Endress + Hauser 111
10.1.7 Certificates and approvals
CE approval The measuring system meets the legal requirements of the EC-guidelines. Endress+Hauser confirms
the instrument passing the required tests by attaching the CE-mark.
Ex approval Correlation of safety instructions (XA) and certificates (ZE) to the instrument:
Overfill protection WHG. See "Ordering structure" on ä 8 - (see ZE 256F/de).
SIL 2, for 4...20 mA output (see SD174F/00/en "Functional safety manual").
Telecommunications Complies with part 15 of the FCC rules for an unintentional radiator. All probes meet the
requirements for a class A digital device (commercial, industrial or business environment). Coax
probes and probes mounted in closed metallic vessels also meet the requirement for a class B digital
device (residential environment).
Instrument Certificate Explosion protection Output Communication KEMA 02
ATEX
XA WHG
FMP40 A non-ex B, G, H HART, 4...20 mA
D PROFIBUS PA
F FOUNDATION Fieldbus
F non-ex + WHG B, G, H HART, 4...20 mA ZE256F/00/de
D PROFIBUS PA ZE256F/00/de
1 ATEX II 1/2 G EEx ia IIC T6
IECEx Zone 0/1
B HART, 4...20 mA 1109 XA164F-
D PROFIBUS PA 1109 XA165F-
F FOUNDATION Fieldbus 1109 XA165F-
6 ATEX II 1/2 G EEx ia IIC T6 + WHG B HART, 4...20 mA 1109 XA164F- ZE256F/00/de
D PROFIBUS PA 1109 XA165F- ZE256F/00/de
2 ATEX II 1/2 D
1)
B, D, F, G,
H
HART, 4...20 mA 1109 XA168F-
3 ATEX II 2 G EEx em [ia] IIC T6
IECEx Zone 1
B HART, 4...20 mA 1109 XA167F-
D PROFIBUS PA 1109 XA167F-
F FOUNDATION Fieldbus 1109 XA167F-
4 ATEX II 1/3 D transp. cover
1)
B, D, F, G,
H
HART, 4...20 mA 1109 XA168F-
5 ATEX II 1/2 G EEx ia IIC T6
ATEX II 1/3 D transp. cover
B HART, 4...20 mA 1109 XA172F-
XA172F-
FOUNDATION Fieldbus 1109 XA172F-
7 ATEX II 1/2 G EEx d [ia] IIC T6 B HART, 4...20 mA 1109 XA166F- ZE256F/00/de
XA166F- ZE256F/00/de
FOUNDATION Fieldbus 1109 XA166F-
8 ATEX II 1/2 G EEx ia IIC T6
ATEX II 1/3 D transp. cover
+ WHG
B HART, 4...20 mA 1109 XA172F- ZE256F/00/de
D PROFIBUS PA 1109 XA172F- ZE256F/00/de
1) In combination with electronics B, D or F: supply intrinsically safe.