Electrical connection Proline Promag W 400
36 Endress+Hauser
Connection examples for standard situations
Metal, grounded pipe
A0016315
10 Potential equalization via measuring tube
Connection example in special situations
For detailed information on special cases, see the Operating Instructions for the device.
• Unlined and ungrounded metal pipe
• Plastic pipe or pipe with insulating liner
• Pipe with a cathodic protection unit
7.3 Hardware settings
7.3.1 Setting the device address
EtherNet/IP
The IP address of the measuring device can be configured for the network via DIP switches.
Addressing data
IP address and configuration options
1st octet 2nd octet 3rd octet 4th octet
192. 168. 1. XXX
↓ ↓
Can only be configured via software addressing Can be configured via
software addressing
and hardware
addressing
IP address range 1 to 254 (4th octet)
IP address broadcast 255