Proline Prowirl R 200 Installation
Endress+Hauser 23
6.2.7 Turning the display module
+
E
1
3mm
A0013905
6.3
Post-installation check
Is the device undamaged (visual inspection)?
Does the measuring device conform to the measuring point specifications?
For example:
Process temperature
Process pressure (refer to the section on "Pressure-temperature ratings" in the "Technical
Information" document on the CD-ROM provided)
Ambient temperature (→  15)
Measuring range
Has the correct orientation for the sensor been selected (→  12)?
According to sensor type
According to medium temperature
According to medium properties (outgassing, with entrained solids)
Does the arrow on the sensor nameplate match the direction of flow of the fluid through the
piping
(→  12)?
Are the measuring point identification and labeling correct (visual inspection)?
Is the device adequately protected from precipitation and direct sunlight?
Are the securing screw and securing clamp tightened securely?