Installation
Requirements Type of tanks
Depending on the type of tank and application, different installation procedures are recommended
for NMS8x.
Type of tanks Without guide system With stilling well With guide wires
Fixed roof tank
Floating roof tank
Covered floating roof tank
Pressurized or bullet tank
Tank with agitator or heavy
turbulence
A stilling well is required in a floating roof tank and a covered floating roof tank.
Guide wires cannot be installed in a floating roof tank. When the measuring wire is exposed
to free space, it may break due to an external shock.
Installing guide wires is not allowed in pressurized tanks because the wires would prevent
closing the valve for replacing the wire, wire drum, or displacer. NMS8x installation position
is important for applications without the guide wire system in order to prevent the measuring
wire from being broken (refer to Operating Instructions for details ).

Table of Contents

Other manuals for Endress+Hauser Proservo NMS81

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Proservo NMS81 and is the answer not in the manual?

Endress+Hauser Proservo NMS81 Specifications

General IconGeneral
BrandEndress+Hauser
ModelProservo NMS81
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals