EasyManuals Logo

Endress+Hauser Prosonic S FMU90 Technical Information

Endress+Hauser Prosonic S FMU90
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TI397F/00/en/04.07
Technical Information
Prosonic S FMU90
Transmitter in housing for field or top-hat rail mounting
for the ultrasonic sensors FDU91/91F/92/93/95/96
Application for level measurement
Continuous, non-contact level measurement of fluids,
pastes, sludge and powdery to coarse bulk materials
with 1 or 2 ultrasonic sensors
Measuring range up to 70 m
(depending on sensor and material measured)
Level limit detection (up to 6 relays)
Pump control (alternating); rake control
Option: additional pump control functions (pump
function test, ...)
Calculations: average, difference, sum
Application for flow measurement
Flow measurement in open channels and measuring
weirs with 1 or 2 ultrasonic sensors
Simultaneous measurement of level and flow in a
stormwater overflow basin with only 1 sensor
Flow measurement with back water detection (2
sensors) or sludge detection
Up to 3 totalizers and 3 (resettable) counters;
optionally resettable via digital inputs
Counting or time pulse output for control of external
units
Your benefits
Simple, menu-guided operation with 6-line plain text
display; 15 languages selectable
Envelope curves on the display for quick and simple
diagnosis
Easy operation, diagnosis and measuring point
documentation with the supplied "ToF-Tool -
FieldTool Package" operating program.
Option: four digital inputs (e.g. for pump feedback)
and one external temperature input
Time-of-flight correction via integrated or external
temperature sensors
Linearisation (up to 32 points, freely configurable)
Linearisation tables for the most common flumes and
weirs pre-programmed and selectable
Online calculation of the flume-/weir-flows via
integrated flow curves
Pre-programmed pump control routines
System integration via HART or PROFIBUS DP
Automatic detection of the sensors FDU9x
The sensors of the former series FDU8x can be
connected (for certificates see note on page 8)

Table of Contents

Other manuals for Endress+Hauser Prosonic S FMU90

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Endress+Hauser Prosonic S FMU90 and is the answer not in the manual?

Endress+Hauser Prosonic S FMU90 Specifications

General IconGeneral
Measurement PrincipleUltrasonic
Protection ClassIP68
Process Temperature-40 to +80 °C
Process Pressure-1 to +3 bar
Output Signal4-20 mA, HART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply24 V DC
CommunicationHART, PROFIBUS PA, FOUNDATION Fieldbus
Housing Materialstainless steel
DisplayLCD