Prosonic S FMU90
4 Endress + Hauser
Linearisation Pre-programmed linearisation curves
Types of vessels
horizontal, cylindrical tank
spherical tank
tank with pyramidal bottom
tank with conical bottom
tank with flat, inclined bottom
Flow curves for flumes and weirs
1)
Khafagi-Venturi flume
ISO-Venturi flume
•BST
2)
-Venturi flume
Parshall flume
Palmer-Bowlus flume
Rectangular weir
Rectangular constricted weir
•NFX
3)
rectangular weir
•NFX
3
rectangular constricted weir
Trapezoidal weir
V-notch weir
•BST
2
V-notch wier
•NFX
3
V-notch weir
The pre-programmed linearisation curves are calculated on-line.
Linearisation formula for flow measurements
1
Q = C (h
α
+ γh
β
)
"h" is the upstream level. The parameters α, β, γ and C can be freely programmed by the user.
Linearisation table
consisting of up to 32 linearisation points; to be entered manually or half-automatically.
Special functions limit detection
rake control
alternating pump control or control according to pump rate (standard)
option: additional pump control functions
4)
:
Alternation accordint to runtime or starts
pump feedback via the optional digital inputs; stand-by pump configurable
pump function test after resting time
storm function to prevent unnecessary pump running times
flush control for regular pump shaft cleaning
pump control according to tariff times via digital input
output of operating hours alarm or pump alarm
recording of pump data (operating hours, number of starts, last running time)
totalising of the flow volume with (resettable) counters and (non-resettable) totalisers
1
triggering of a sampler by time or quantity pulses
1
low flow cut off
1
backwater detection in flumes
1
sludge detection in flumes
1
trend detection
Datalog functions Peak hold indicator of the min./max. levels or flows and the min./max. temperatures at the sensors
Recording of the last 10 alarms
Indication of the operating status
Trend indication of the outputs on the on-site display
Indication of the operating hours
1) for instrument versions with flow software (FMU90 - *2**********)
2) BST: British Standard
3) French standard NFX 10-311
4) for instruments with software for additional pump control (FMU90-*3********** or FMU90-*4**********)