Prosonic T Mounting
Endress+Hauser 9
L00-FMU30xxx-17-00-00-xx-004
BD: Blocking distance; SD: safety distance; E: empty calibration; F: full calibration (span); D: nozzle diameter;
L: nozzle length
"
Caution!
If the blocking distance is undershot, it may cause device malfunction.
F
E
BD
SD
L
D
Nozzle diameter
Maximum nozzle length mm (in)
1½" sensor 2" sensor
DN50/2" 80 (3.15)
DN80/3" 240 (9.45) 240 (9.45)
DN100/4" 300 (11.8) 300 (11.8)
DN150/6" 400 (15.7) 400 (15.7)
DN200/8" 400 (15.7) 400 (15.7)
DN250/10" 400 (15.7) 400 (15.7)
DN300/12" 400 (15.7) 400 (15.7)
Emitting angle α 11° 11°
Blocking distance [m (ft)] 0.25 (0.8) 0.35 (1.1)
Max. range [m(ft)] in liquids 5 (16) 8 (26)
Max. range [m (ft)]
in solids
2 (6.6) 3.5 (11)