Prothermo NMT81 Installation
Endress+Hauser 31
Non-height adjuster type of NMT81
Make sure to align the correct orientation position of the device prior to tightening bolts.
L
CAUTION
Cable damage
It may cause the damage of the cable inside.
Do not rotate the housing with loosening the socket head cap screw mounted on the side of
the converter.
Installation procedure for thread type
Tighten the reducer securely.
Tightening torque: 255 Nm
L
CAUTION
Precautions regarding Stranded wire on anchor weight and top anchor
Applying tension of more than 6 kg (13.23 lb) may cause internal damage in the temperature
probe.
Ensure that the tension during and after installation is no more than 6 kg (13.23 lb).
1
M
1
2
M
A0042790
 20 Installation of anchor weight/top anchor
M During/after installation: M ≤ 6 kg (13.23 lb)
1 Lowest temperature element position
2 Hook