5.2.3 Display
a0014551
Fig. 22: Display of the batch controller (example)
1: Display group 1: no batch active. Flow, temperature, preset counter
2: Display group 2: batch active. Flow, volume counter, preset counter
!
Note!
A list of the icons is provided in the Appendix in the operating instructions.
5.2.4 "FieldCare Device Setup" operating software
For configuring the device using the FieldCare Device Setup software, connect the device to
your computer via the USB interface.
Establishing a connection
Proceed as follows:
1. Start FieldCare.
2. Connect the device to the computer via USB.
3. Generate project via File/New.
4. Select communication DTM (CDI Communication USB).
5. Add EngyCal
®
RH33 or RS33.
6. Click "Establish connection".
7. Start online configuration.
Carry out the rest of the configuration of the device according to these Operating Instructions
for the device. The entire Setup menu, i.e. all parameters listed in these Operating Instructions,
is also included in the FieldCare Device Setup.
!
Note!
During configuration with FieldCare, the device can enter undefined states! This can result in
undefined switching of outputs and relays.