Frontier Gas Heat – PN 10-2027 – June 2018 4
FOR YOUR SAFETY READ BEFORE OPERATING
A. This burner does not have a pilot. It is
equipped with an ignition device which
automatically lights the burner. Do not try
to light the burner by hand.
C. Use only your hand to turn the gas control
knob. Never use tools. If the knob will not
turn by hand, don’t try to repair it, call a
qualified service technician. Force or
attempted repair may result in a fire or
explosion.
B. Before OPERATING, smell all around the
boiler area for gas. Be sure to smell next to
the floor because some gas is heavier than
air and will settle on the floor. See below.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas
supplier’s instructions.
If you cannot reach your gas supplier, call
the fire department.
D. Do not use this boiler if any part has been
under water. Immediately call a qualified
service technician to inspect the boiler and
to replace any part of the control system
and any gas control, which has been under
water.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above.
2. Set the thermostat(s) to their lowest setting.
3. Turn off all electrical power to the burner/boiler.
4. This burner is equipped with an ignition device which automatically lights the burner.
5. Do not try to light the burner by hand.
6. Turn Gas control knob clockwise to OFF.
7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you
smell gas, STOP! Follow the safety information above. If you don’t smell gas, go to the next
step.
8. Turn Gas control knob counterclockwise to ON.
9. Set thermostat(s) to desired setting.
10. Turn on all electric power to the burner and boiler.
11. If the burner/boiler will not operate, follow the instructions “TO TURN OFF GAS TO THE
BURNER” below and call your service technician or gas supplier.
TO TURN OFF GAS TO THE BURNER
1. Set thermostat(s) to their lowest setting.
2. Turn off all electric power to the burner and boiler if service is to be performed.
3. Turn Gas control knob clockwise to OFF. Do not force.
WARNING: If you do not follow these instructions exactly, a fire or explosion
ma
result causin
ro
ert
dama
e,
ersonal in
ur
or loss of life.