C048-725-30 Rev. B (01/2020)
5.5.5 5.5.5 “SETUP ADVANCED HOLD 3 S” – “SETUP ADVANCED HOLD 3 S” –
Advanced Settings MenuAdvanced Settings Menu
The advanced menu contains the following functions�
Changing these settings or using these functions may
a󰀨ect the monitoring capabilities of the panel.
Restore Defaults
Resets all of the panel settings back to factory default�
This will clear breaker inventory and set the breaker
ampacity, warning, and alarm thresholds back to their
default settings�
Setup Demo
This assigns fake values to current and breaker inventory
for demonstration purposes� It should not be used during
normal operation�
System Info
This displays the rmware version installed on the 
controller
5.6 5.6 Review System Status via the Review System Status via the
Embedded Web ServerEmbedded Web Server
This section applies to the Matrix family products with the
optional embedded web server installed� If a panel does
not have an Ethernet web server but you would like to add
one, or if you are unsure if this option is installed on your
panel, contact Alpha Support�
The optional embedded Ethernet module provides remote
monitoring via IP-based Ethernet networks and a web
browser� To view the system status, you will need to
connect the Ethernet port on the rear of your Matrix to
your network� See "4�9 Installing the Network Cable" on
Page 14 for information on installing the network cable�
By default, the Ethernet module is congured from the 
factory with a static IP address and network settings, as
dened below.
5.6.1 5.6.1 Default Static Network SettingsDefault Static Network Settings
Set up a local network to communicate with the embedded
web server at the following network settings:
y IPV4 Address: 192�168�123�123
y Subnet Mask: 255�255�255�0
y Default Gateway: 192�168�123�1
y Primar y DN S: 192�168�12 3�1
y Secondary DNS: 8�8�8�8
Once you establish a connection to the embedded
Ethernet module, use the following credentials to gain
access to the protected data and administrative pages:
y Username: root
y Password: password
SETUP
ADVANCED
HOLD 3 S

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EnerSys alpha Matrix C16 and is the answer not in the manual?

EnerSys alpha Matrix C16 Specifications

General IconGeneral
BrandEnerSys
Modelalpha Matrix C16
CategoryPower distribution unit
LanguageEnglish