EasyManua.ls Logo

Engbo XForce Series - Wireless Remote Battery Replacement; Wireless Remote Control Specifications

Engbo XForce Series
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XF Rev: 7, 2008-10-14 Page 7
Replace the rubber cover.
• Start by pushing the rubber cover in by the antenna and continue
around the edge until the cover is fixed in place.
• Make sure not to twist the cover with the antenna.
(The remote control will function over short distances even without the
antenna.)
2.4.2 Battery replacement
The remote control uses three regular AAA/LR03 alkaline batteries. The
battery life is more than two seasons under normal leisure use.
When replacing batteries, open the unit by unscrewing all five screws.
NB:
• The screws are of different lengths and have O-rings under the screw
heads.
• Replace the batteries and make sure all point the same way with the
+ up and the – downwards towards the edge as illustrated.
• Reassemble the back cover and carefully screw the parts together
until the housing gasket is slightly compressed. The remote will
remain waterproof as long as the O-rings and gasket are intact with
correct compression.
NB: To ensure a long lifetime, this remote control has acid-proof machine
screws and screw inserts in the housing. The screws may penetrate the
housing if screwed carelessly or too much force is used.
(Not covered by the warranty.)
3 TECHNICAL SPECIFICATIONS WIRELESS REMOTE CONTROL
Wireless remote:
Motor Control Unit:
Model:
RC-01 ECU-01
Power supply:
3 x 1.5 V DC
(3 x AAA/LR03 batteries)
From thruster (integrated)
Battery life:
2–3 years (normal leisure use) Not applicable
Communication:
Two-way, narrowband, GFSK modulation
Operating frequency:
868.075 – 869.125 MHz, CE (EU/EFTA)*
902.175 – 903.025 MHz, FCC (US/Canada)*
Channels:
16 for communication
Channel separation:
50 kHz
Address range:
65.535 (16 bit), spread among the 16 channels
Temperature range:
-20 to +60 degrees Celsius/-4 to +131 degrees Fahrenheit
Relative humidity
(without condensation):
20% – 90%
Weight:
105 g Model dependent
Dimensions (HxWxD):
127x53x22 mm Model dependent
Environment protection:
(Floating)**
IP 68** IP 41
* May apply to other countries. For information, please contact local authorities for the country concerned.
** Conditional upon correct installation and intact rubber gasket and O-rings.

Table of Contents