9 Decals
9.1.6. 9000258
USER 1/SHEAR
9000258-C
2 SEC
3 SEC
Not
installed
FNR
AUTO
EXTRA
2
+
EXTRA
1
9.1.6.1. How to activate double-acting function
3 SEC
Box
Description
1
Disconnect the connector on the stick.
2
Buzzer sounds.
3
Hold down the button in the MIG2 grip for 3 seconds (until a constant tone switches to
short beeps).
4
Double-acting function activated.