9. TECHNICAL SPECIFICATION
Envirotainer RKN e1 Container
9. TECHNICAL SPECIFICATION
REFRIGERATING SYSTEM
Thermostat-controlled air conditioning system with compressor cooling and electrical heating.
Powered by rechargeable batteries.
Recharging power supply 100-240 V AC, 50-60 Hz
Maximum power consumption during
charging
1850 W
Maximum charging time 8 h
Container set temperature range
0°C to +20°C (+32°F to +68°F)
Temperature tolerance in cargo space
at set temp 0 to +10°C (+32°F to +50°F) +/- 3°C (+/- 5.4°F)
at set temp +10°C to +20°C (+50°F to +68°F) +/- 5°C (+/- 9°F)
Autonomy at container set temperature +5°C
(41°F)
30 h
Operation range at container set temperature
+5°C (41°F), ambient conditions
1
-20°C to +40°C (-4°F to +104°F)
Storage temperature range
Storage temperature range -40°C to +50°C
(-40°F to +122°F)
DIMENSIONS
External cube (volume) 4.8 m
3
(169.6 foot
3
)
External dimensions (L x W x H)
2000 x 1535 x 1620 mm
(78.7 x 60.4 x 63.8 in)
Internal dimensions (L x W x H) 1340 x 1319 x 1315 mm
(52.7 x 51.9 x 51.7 in)
Door opening (L x H) 1340 x 1315 mm
(52.7 x 51.9 in)
Internal cube (volume)
2.3 m
3
(81.9 foot
3
)
WEIGHT
Tare weight 635 kg
(1,400 lbs)
Max gross weight 1,588 kg
(3,500 lbs)
Max net weight
2
953 kg
(2,100 lbs)
OTHER INFORMATION
Suitable for use on aircraft A300, A310, A330, A340, A380, B747, B767, B777, DC10, IL86,
MD11, L1011. For other aircrafts, alternative operating procedures may apply.
Forkliftable with a slot-height of 95 mm (3.7 in), slot-width of 290 mm (11.4 in).
1. please refer to test report "TR120013" for load specification.
2. The tare weight (and thereby the max net weight) may change due to repairs, see manufacturer´s plate for
correct weight.
Doc No. MO-RKN-3009