11. RKN E1 CONTAINER CHECK LIST
Envirotainer RKN e1 Container
11. RKN E1 CONTAINER CHECK LIST
For Refrigerated and Controlled Room Temperature Products
Start the container by pressing without the container being connected to the electrical
outlet. The indicators on the display unit are lit to test functionality. If the container does
not start, ensure the container battery switch is on.
Container Charging
Connect container to AC power outlet to charge the batteries.
Ensure the blue charging light is lit (flashing or fixed).
Container Pre-Conditioning
(If pre-conditioning is performed with container operating in non temperature-controlled area).
Perform a functional test of container.
Make sure container doors are properly closed.
Set container temperature to the desired container set temperature.
Wait at least 30 minutes before loading cargo.
(If pre-conditioning is performed with a temperature-controlled room).
Perform a functional test of container.
Place the container in a temperature-controlled room that is set to the desired temperature.
Make sure container doors are open.
Wait at least one hour before loading cargo.
Container Loading
Ensure product, packing material & container is pre-conditioned prior to loading.
Minimize exposure of product to ambient temperatures during loading into the container.
Place cargo on pallet or spacers at least 20 mm (0.8") to ensure sufficient airflow between
cargo and floor.
Make sure no boxes are loaded in a way that blocks the airflow between the spacers inside
container walls.
Secure the cargo using the container’s tie-down brackets.
Close and secure the container doors.
Check that no alerts are active.
Make sure the blue charging light is fixed (not flashing) before disconnecting from AC power.
Ensure all charging equipment is correctly stowed in the charging unit, and that all adapters
are in place.
Transport / Handling / Storage
Charge container whenever possible.
Comply with specified limits and conditions.
Doc No. MO-RKN-3009
Version 2.2: 2017-08-31 40 (42)