EasyManuals Logo

Envision ENV200 User Manual

Default Icon
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #179 background imageLoading...
Page #179 background image
P a g e | 179
12 Problems and Potential Solutions for Envision and Handheld Device
Problem
Potential Solution
Handheld device will not Connect to the
Envision by Bluetooth
-Check the home screen on the handheld to insure the WLAN is
OFF
-Check the Envision to make sure the blue light is flashing next
to the Bluetooth button
-Check the home screen on the handheld to insure the
Bluetooth is ON
The Elkins Gas Analyzer software will not
turn on
The synchronizing setting for the Nomad has the Files box is
selected for Nomad to the Computer. Unselect the files box and
remove all your Field Data files from the Nomad.
Handheld device will not read GPS
-Make sure that Sat Viewer is turned off.
-Check the settings on the handheld device to make sure they
match the settings in section 5.5 of this document for GPS
The lighting on the Nomad is dull
Press the green power button for just a second
O
2
reading seems high
-Check the filters and make sure that they are tight
-Change the O-ring’s on the quick connect fittings
-Make sure your hoses have no holes
The screen is dark
Adjust your backlight setting to match section 5.3 of this
document. Also you can just hit the power button for a second.
CH
4
is over 1000%
The reading may be set to CH
4
LEL. Click the CH
4
box to toggle
from normal reading to LEL reading.
If you are experiences an issue that is not listed above, or the solution above did not solve the issue,
please contact Elkins Earthworks® for further troubleshooting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Envision ENV200 and is the answer not in the manual?

Envision ENV200 Specifications

General IconGeneral
BrandEnvision
ModelENV200
CategoryMeasuring Instruments
LanguageEnglish