Script Mode
UI # UI mode
U 100 # Output voltage 100 V
I 10 # Output current 10 A
LOOPCNT 10 # Start address
RUN # Activate output
DELAYS 10 # Wait 10s
STANDBY # Deactivate output
DELAYS 10 # Wait 2s
PMAX - maximum output in UIP mode
Maximum output for the UIP mode.
PV - Pv
sim
mode
Activates the PV
sim
mode.
Example:
PVSIM #Activate PV simulation
RI - Internal resistance UIR mode
This command adjusts the set point for the internal resistance in UIR mode.
RUN - Activate output
The command
RUN
resets the standby mode and activates the output.
Example:
RUN # Activate output
STANDBY - Deactivate output
The command
STANDBY
deactivates the output and activates standby mode.
Example:
STANDBY # Deactivate output
U - Set point output voltage
Set point for output voltage in V.
Example:
U 100 # Output voltage 100 V
UI - UI-Modus
This command activates the UI mode. Unit works current and voltage regulated.
Example:
UI # UI mode
UIP - UIP mode
This command activates the UIP mode. Unit works current, voltage and power regulated.
UIR - UIR mode
This command activates the UIR mode. Unit works current and voltage regulated. Additionally, an internal resistance
is simulated.
UMPP - Set point UMPP voltage
Set point for MPP voltage for PV simulation in V.
Example:
UMPP 80.42 # MPP voltage 80.42 V