Symptom Cause Solution
Image is too dark.
One or more of the toner
cartridges may be defective.
Remove the toner cartridges and check for damage. If it is
damaged, replace it.
The photoconductor unit may
be defective.
Remove the photoconductor unit and check for damage. If it
is damaged, replace it.
Image is blurred;
background is
lightly stained;
there is insufficient
gloss of the
printed image.
One or more of the toner
cartridges may be defective.
Remove the toner cartridges and check for damage. If it is
damaged, replace it.
The photoconductor unit may
be defective.
Remove the photoconductor unit and check for damage. If it
is damaged, replace it.
The print or color
density is uneven.
One or more of the toner
cartridges may be defective or
low.
Remove the toner cartridges and check for damage. If it is
damaged, replace it.
The photoconductor unit is
defective.
Remove the photoconductor unit and check for damage. If it
is damaged, replace it.
The printer is not level. Place the printer on a flat, hard, level surface.
Irregular print or
mottled image
appears.
The media is moist from
humidity.
Adjust the humidity in the media storage area.
Remove the moist media and replace it with new, dry media.
Unsupported media (wrong size,
thickness, type, etc.) is being
used.
Use Epson-approved media. See “Print Media” on page 25.
One or more of the toner
cartridges may be defective.
Remove the toner cartridges and check for damage. If it is
damaged, replace it.
The photoconductor unit is
defective.
Remove the photoconductor unit and check for damage. If it
is damaged, replace it.