48
Setting the DIP Switches
DM-D500 is provided with two DIP switches. DIP switch settings are loaded the next time the DM-D500 is
turned on.
In a stand-alone connection, set the same settings for communication (data length, parity, baud rate) for DM-
D500 as for the computer.
In a path-through connection, set the same settings for communication (data length, parity, baud rate) for all,
including the computer and printer.
In a Y connection, the settings for communication must be the same for the computer and customer display. In
addition, set DIP switch 2-1 to ON.
In an USB controlled (serial), set the transfer speed to 19200 bps.
Functions that can be set with the DIP switches are as follows.
DIP switch 1
(*1) "XON/XOFF" is valid only for stand-alone connections.
(*2) In OPOS and APD4, use the DIP switch in default setting: "DTR/DSR".
Transfer speed switching
DSW1
No.
Function ON OFF
Default
setting
1-1 Error Data Reception Ignore "?" display OFF
1-2 Handshake XON/XOFF (*1) DTR/DSR (*2) OFF
1-3 Data Length 7 bits 8 bits OFF
1-4 Parity Yes No OFF
1-5 Parity Selection Even Odd OFF
1-6 Baud Rate Switching See "Transfer speed switching" ON
1-7 OFF
1-8 ON
SW1-6 SW1-7 SW1-8
Transfer speed
(bps)
ON ON ON 2400
OFF ON ON 4800
ON OFF ON 9600
(Default setting)
OFF OFF ON 19200
ON ON OFF 38400
OFF ON OFF 57600
ON OFF OFF 115200