Maintenance Cartridge Specifications
Type Maintenance cartridge for waste ink.
Number installed 1
Environmental conditions In the packaging: -20 to 40 ˚C (temperature), 20 to 85% (humidity)
Installed in printer: Conforms to the general specifications below
Transporting: -20 to 60 ˚C (temperature) 5 to 85% (humidity) (within one month at 40 ˚C, 120 hours
at 60 ˚C)
Cartridge dimensions 78.8 (W) x 254.5 (D) x 38.5 (H) mm
General Specifications
Temperature Operating: 10 to 35 ˚C
Storage (before unpacking): -20 to 60 ˚C (within 120 hours at 60 ˚C, one month at 40 ˚C)
Storage (after unpacking): -20 to 40 ˚C (within one month at 40 ˚C)
Humidity Operating: 20 to 80% (without condensation)
Storage (before unpacking): 5 to 85% (without condensation)
Storage (after unpacking): 5 to 85% (without condensation)
Weight Approx. 23 kg (printer only)
Dimensions 460 (W) x 430 (D) x 354 (H) mm
U “Necessary space” on page 98
Standards and Approvals
Safety UL 60950-1
CAN/CSA No. 60950-1
Low Voltage Directive 2006/95/EC EN 60950-1
EMC FCC part 15 subpart B class A
CAN/CSA-CEI/IEC CISPR 22 Class A
AS/NZS CISPR 22 Class A
EMC Directive 2004/108/EC EN 55022 Class A
EN 55024
EN 61000-3-2
EN 61000-3-3
!
Warning:
This is a class A product. In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.