EPSON Stylus CX4900/CX4905/CX5000/DX5000/DX5050/CX5900/CX6000/DX6000/DX6050 Revision A
ADJUSTMENT Adjustment Except Adjustment Program 187
5.3.3  Original Adjustment
 Parts to be removed and replaced
 Replacement of Scanner Housing, Upper
 Replacement of Scanner Unit
 Adjustment procedure
1. Hold down [Color Start] + [Paper Size]+ [Fit to Page] and turn the printer on. 
Keep pressing those buttons for five seconds, and the printer turns to the 
scanner mode.
* This adjustment can be performed by turning on the printer without pressing 
those buttons. However, following the above approach reduces the time taken to 
enter ready mode.
2. Run “FT.exe”.
Figure 5-24.  Original Adjustment (1)
3. Open the document cover, and place the original adjustment jig as shown in 
the figure below.
Figure 5-25.  Original Adjustment Jig Setting Position
4. Select “Celadon” in the “Select Parameter Set” window, and click [OK].
Figure 5-26.  Original Adjustment (2)
C A U T I O N
 This adjustment requires the FT (Function Test) program and 
the exclusive adjustment jig.
 If the setting of the printer differs from the one mentioned in the 
following procedure, this adjustment can not be completed 
correctly. In that case, the edge of the Scanner Housing, Upper 
may be read in during scanning or copying.
C H E C K
P O I N T
 Download and install the Original Adjustment program from 
TechExchange.
 Before the adjustment is performed, connect the printer to the 
computer with the adjustment program installed with the USB 
cable.
Original Adjustment Jig
Place the jig against the upper left corner 
of the Scanner Housing, Upper