EasyManua.ls Logo

Epson Stylus Pro 3800 - Page 39

Epson Stylus Pro 3800
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Epson Stylus Pro 3800/3800C/3850/3880/3885/3890 Revision C
OPERATING PRINCIPLES Overview 39
Sensors/Encoders/CSIC
Figure 2-3. Layout of Sensors/Encoders/CSIC
Table 2-3. List of Sensors/Encoders/CSIC
Fig. Name Function Specifications
ASF phase sensor
Detects the ASF origin
position.
Type: Transmissive photo interrupter
Voltage: 3.3 VDC
± 5 %
Release sensor
Detects an open/closed
state of the release roller.
Type: Transmissive photo interrupter
Voltage: 3.3 VDC
± 5 %
PF encoder Reads the PF scale.
Type: Linear encoder (180LPI)
Voltage: 3.3 VDC
± 5 %
Ink cover sensor
Detects an open/closed
state of the ink cover.
Type: Mechanical contact
Voltage: 3.3 VDC ± 5 %
Pressure pump home
sensor
Detects the home
position of the pressure
pump.
Type: Mechanical Contact
Voltage: 3.3 VDC
± 5 %
Pressure sensor
Detects the state of
pressurization by the
pressure pump.
Type: Reflective photo interrupter
Voltage: 3.3 VDC
± 5 %,
Comparator input
Board paper tray open
sensor
Detects the position of
the board paper tray.
Type
:
Mechanical Contact
Voltage: 3.3 VDC ± 5 %
Ink cartridge sensor
CSIC that stores ink
cartridge information
Type: CSIC
Voltage: 3.3 VDC ± 5 %
PG origin sensor
Detects the origin
position of the platen
gap.
Type: Transmissive photo interrupter
Voltage: 3.3 VDC
± 5 %
v
Ink change sensor
Detects the state of the
black ink switch lever.
Type: Mechanical contact
Voltage: 3.3 VDC
± 5 %
Ink mark sensor
Auto Bi-D adjustment
Auto
Uni-D
adjustment
Auto nozzle check
Type:
Diffuse reflective photo interrupter
Voltage: 3.3 VDC ± 5 %, LED: 5 V
Maintenance cartridge
cover sensor
Detects an open/closed
state of the maintenance
cartridge cover.
Type: Mechanical contact
Voltage: 3.3 VDC ± 5 %
PW sensor
Paper leading edge
detection
Paper width detection
Type: Reflective photo interrupter
Voltage: 3.3 VDC ± 5 %, LED: 3.3 V
Maintenance cartridge
sensor
CSIC that stores
maintenance cartridge
information.
Type: CSIC
Voltage: 3.3 VDC
± 5 %
1
2
3
4
5
6
7
8
9
10
11
12
13
14
PE sensor
Detects a rear edge of
paper.
Type: Transmissive photo interrupter
Voltage: 3.3 VDC
± 5 %
CR encoder Reads the CR scale.
Type: Linear Encoder (180LPI)
Voltage: 3.3 VDC ± 5 %
Table 2-3. List of Sensors/Encoders/CSIC
Fig. Name Function Specifications
15
16
16
15
14
9
3
10
12
8
2
11
1
4
5
6
7
13