Epson Stylus Pro 3800/3800C/3850/3880/3885/3890 Revision C
ADJUSTMENT Reset Counters 268
5.5 Reset Counters
Whenever replacing a part/unit whose service life is counted by the counter, the
corresponding counter must be reset immediately after installing a new one.
Purpose
To exchange parts in an appropriate timing, keep the counter counts managed
precisely.
Procedure
1. Turn the printer ON.
2. Start up the Adjustment Program and select the applicable counter reset menu.
3. Click [Run] to reset the counter.
4. Click [Finish].
Figure 5-87. Counter Reset Screen
Table 5-5. Counter Reset List
Replaced Parts Name Reset Menu Name
PUMP, CAP, ASSY Reset When Cleaning Unit Change
Reset When Pump Motor Change
PRINT HEAD Reset When Print Head Change
INK, SYSTEM, ASSY Reset When INK SYSTEM ASSY Change
POROUS PAD, TRAY, INK EJECT Reset When Ink Holder Waste Absorber Change
POROUS PAD, INK WASTE BOX, RIGHT/
POROUS PAD, INK WASTE BOX, LEFT
Reset When Borderless Absorber Change
MOTOR ASSY., CR Reset When CR Motor Change
ASF, ASSY Reset When ASF Unit