Stylus Pro 4000 Field Repair Guide 4/28/05
Main Board Replacement Printer Component, Software Item, LCD Display, Printer Button Page 56.
15. Down load the current firmware version.
15.1 Open the PRNPRINT application, and prepare to send the current firmware version to the Printer.
15.2 Turn on the Printer while depressing the Left, Up, Down, and Right arrow buttons, The Printer will display
UPDATE F/W.
15.3 Send the current firmware to the Printer.
16. Re-Install the Printer’s parameters using the Parameter Backup / Restore Utility (Nvram.exe)
16.1 Perform the RTC&USBID&IEEE1394ID Adjustment.
If the Printer’s Parameters are not available skip step 16, and follow step 17.
17. Perform the following operations in the order listed.
17.1 Stop the Printer from priming (See The Prime ON / Off chapter).
17.1.1 Note: Init.Fill: Reset = The Printer ‘s prime function is turned off.
17.2 Perform the Rear Sensor AD Adjustment.
17.3 Perform the Cutter Pressure adjustment.
17.4 Perform the Platen Gap adjustment.
17.5 Enter the Head Rank ID (Print Head calibration values).
17.6 Perform the Multi Sensor Level Adjustment.
17.7 Perform the Print Head Slant (CR) Adjustment.
17.8 Perform the Print Head Slant (PF) Adjustment.
17.9 Perform the Multi Sensor Adjustment for Auto Nozzle Check.
17.10Perform the Nozzle Bi-D Adjustment.
17.11Perform the Auto Bi-D Adjustment.
17.11.1Copy Bi-D variables
17.12Perform the Auto Uni-D Adjustment.